If you believe that your paper was mistakenly rejected by other leading journals and you do not agree with final decision, the editors of Reports of Practical Oncology and Radiotherapy offer new fast track review. You may submit your manuscript to Reports of Practical Oncology and Radiotherapy together with all prior peer-reviews obtained from the other journal and your rebuttal letter. We guarantee review based decision within 72 hours from the time we will receive your manuscript.

Fast track submission process: Please submit the manuscript with all reviews and rebuttal letter by email to Dr. Michal Masternak (michal.masternak@ucf.edu) for fast review processing. To assure immediate attention the email title must to include: RPOR-fast track- Last Name First Name (of corresponding author).

Volume 22, Number 1, 2017

Effects of Siemens TT-D carbon fiber table top on beam attenuation, and build up region of 6 MV photon beam

Asma Sheykhoo, Sara Abdollahi, Mohammad Hadi Hadizadeh Yazdi, Mahdi Ghorbani, Mohammad Mohammadi

Summary:

Aim

This study deals with Monte Carlo simulations of the effects which the 550 TXT carbon fiber couch can have on the relevant parameters of a 6 MV clinical photon beam in three field sizes.

Background

According to the reports issued by the International Commission on Radiation Units and Measurements (ICRU), the calculated dose across a high gradient distribution should be within 2% of the relative dose, or within 0.2 cm of the isodose curve position in the target volume. Nowadays, the use of posterior oblique beam has become a common practice. It is clear that, in radiotherapy, the presence of the couch affects the beam intensity and, as a result, the skin dose.

Materials and methods

Firstly, Siemens linear accelerator validation for 6 MV photon beam was performed, and satisfactory agreement between Monte Carlo and experimental data for various field sizes was observed. Secondly, the couch transmission factor for the reference field size and depth was computed, and the skin dose enhancement by the couch was assessed.

Results

The largest impact of the carbon fiber couch effect was observed for the 5 × 5 cm2 field size. Such evaluation has not been reported for this couch before.

Conclusion

Despite providing minimal attenuation for the primary radiation, the assumption that carbon fiber couches are radiotranslucent is not valid, and the effects of couches of this type on the transmission factor, and on the skin dose should be carefully investigated for each field size and depth.

Signature: Rep Pract Oncol Radiother, 2017; 22(1) : 19-28