Dear Authors,
If you believe that your paper was mistakenly rejected by other leading journals and you do not agree with final decision, the editors of Reports of Practical Oncology and Radiotherapy offer new fast track review. You may submit your manuscript to Reports of Practical Oncology and Radiotherapy together with all prior peer-reviews obtained from the other journal and your rebuttal letter. We guarantee review based decision within 72 hours from the time we will receive your manuscript.

Fast track submission process: Please submit the manuscript with all reviews and rebuttal letter by email to Dr. Michal Masternak (michal.masternak@ucf.edu) for fast review processing. To assure immediate attention the email title must to include: RPOR-fast track- Last Name First Name (of corresponding author).

Volume 6, Number 1, 2001

Validation of conformal radiotherapy treatment planning systems using an antropomorphic phantom and thermoluminescence dosimetry

Waligórski MPR, Lesiak J, Byrski E, Rozwadowska-Bogusz B, Barańczyk R, Góra E, Bilski P, Olko P.

Summary:

Within the requirements of a Quality Assurance programme in a radiotherapy department, the ability of a treatment planning system (TPS) to accurately calculate dose distributions under realistic conditions encountered in radiotherapy (RT) should be validated. This may be accomplished by thermoluminescence (TL) dosimetry in simulated treatment of antropomorphic phantoms. In our radiotherapy department, several planning systems are used concurrently in 3D conformal treatment of larger volumes (with irregular fields obtained via individual shielding or multileaf collimation) and of very small volumes (stereotactic technique), by external megavoltage photon beams. Realistic 3D treatment plans were prepared using CadPlan, Theraplan and BrainLab TPS for treating volumes in an Alderson phantom, which was prepared for topometry (CT-scanned) and irradiated in fully simulated conditions of patient RT. Suitably selected TL detectors (some custom-produced for these measurements), were placed inside and around the treated volumes in the phantom. For every photon beam applied (Co-60, 6 MV or 9 MV) the TL detectors, individually corrected, were calibrated in a standard solid phantom against ionisation chamber dosimetry. For irradiation of larger volumes, standard MTS-N (LiF:Mg,Ti) detectors were used. For stereotactic irradiation of small volumes in the head (6 MV) special miniature thermoluminescent LiF:Mg,Ti and LiF:Mg,Cu,P were developed. The technique of detector calibration, preparation of Alderson phantom for simulated RT, detector readout and interpretation of the measured versus calculated values of dose at measurement points inside the phantom, will be described.

Signature: Rep Pract Oncol Radiother, 2001; 6(1) : 38-38


« back

 
INDEXED IN:

Indexed in: EMBASE®, the Excerpta Medica database, the Elsevier BIOBASE (Current Awareness in Biological Sciences) and in the Index Copernicus.

http://www.sciencedirect.com/science/journal/15071367/19/2