Dear Authors,
If you believe that your paper was mistakenly rejected by other leading journals and you do not agree with final decision, the editors of Reports of Practical Oncology and Radiotherapy offer new fast track review. You may submit your manuscript to Reports of Practical Oncology and Radiotherapy together with all prior peer-reviews obtained from the other journal and your rebuttal letter. We guarantee review based decision within 72 hours from the time we will receive your manuscript.

Fast track submission process: Please submit the manuscript with all reviews and rebuttal letter by email to Dr. Michal Masternak (michal.masternak@ucf.edu) for fast review processing. To assure immediate attention the email title must to include: RPOR-fast track- Last Name First Name (of corresponding author).

Volume 11, Number 5, 2006

Dosimetric verification of the dose distribution in pulsed dose rate brachytherapy

Joanna Lipińska, Grzegorz Zwierzchowski

Summary:

Background Pulsed dose rate (PDR) brachytherapy is clinically used as an irradiation technique.
It combines the physical advantages of high-dose-rate (HDR) technology
(isodose optimization, planning flexibility and radiation safety) with the radiobiological advantages of low-dose-rate (LDR) brachytherapy [1,2]. The single radioactive stepping source moves through all the implanted catheters during each pulse. The source is enclosed in a capsule 2.5mm long with a diameter of 1.1mm [3]. The resulting isodoses can be optimized by modulating the dwell time of the
source as a function of its trajectory within the implanted volume.
Aim The aim of this study was the dosimetric verifi cation (in-phantom) of doses calculated with the Plato treatment planning system (TPS) by using GafChromic films and thermoluminescent detectors (TL) in PDR brachytherapy.
Materials/Methods Absorbed doses at chosen points were measured with TL detectors, while dose distributions were measured with GafChromic films. Dose measurements were made at 14 reference points in a specially designed, tissue equivalent phantom.
The prescribed doses were compared with the measured doses. A fusion of two
dose distributions was made. The image read from the dosimetric fi lm after its
digitalization was fused with the one received from TPS. Qualitative analysis of this fusion was performed.
Results Wilcoxon test and sign test (dependent samples) were used to compare the doses calculated with those measured with TL detectors. The statistical comparison of doses calculated and measured revealed differences in the range of – 14.7%
to 12.6%. These results fi tted well with the results of qualitative analysis made using images’ fusion made for calculated and measured dose distributions.
Conclusions Both quantitative and qualitative analysis proved the correctness of the calculation
algorithms used by the Plato planning system in a phantom study for PDR
brachytherapy.

Signature: Rep Pract Oncol Radiother, 2006; 11(5) : 223-228